COMMAND CODE TITLE:
76
Y
No.
MEANING
term
39
D
Ringer Tone
Pattern for DID
incoming call with
no CLI
[Series 3600]
NOTE 1:
This command is effective when CM76 Y=34, 36 is set to 0 or 2, and D
NOTE 2:
For details of the Ringer Tone Pattern see
40
Kind of call
termination
indicator key/lamp
on Attendant con-
sole for DID
incoming call with
no CLI
[Series 3600]
NOTE:
The command is effective when CM76 Y=34, 36 is set to 0, and the destination of call forwarding is
Attendant console.
41
Mobility Access
function to each
DID number
[Series 3700
R12.1]
90
Number Conver-
sion Block No. for
Development
Table 1
DIGIT CONVERSION ON DID CALL
1ST DATA
000-999:
Number Conver-
sion Block No.
assigned by
CM76 Y=00/90
000-999:
Number Conver-
sion Block No.
assigned by
CM76 Y=00/90
000-999:
Number Conver-
sion Block No.
assigned by
CM76 Y=00/90
X-XXXXXXXX:
DID number
NONE
2ND DATA
DATA
MEANING
0
Ringer Tone Pattern 0
1
Ringer Tone Pattern 1
2
Ringer Tone Pattern 2
3
Ringer Tone Pattern 3
4
Ringer Tone Pattern 4
5
Ringer Tone Pattern 5
6
Ringer Tone Pattern 6
7
As per CM76 Y=23
CM65
Y=40.
0
C.O. Incoming Call 0
1
C.O. Incoming Call 1
6
C.O. Incoming Call 6
7
As per CM35 Y=15
0
To use Mobility Access termination
1
To set Mobility Access mode
2
To cancel Mobility Access mode
7
Not used Mobility Access function
000
Number Conversion Block No. 000
999
Number Conversion Block No. 999
No data
– 539 –
: Initial Data
REMARKS
CM65 Y=90
CM76 Y=23,
34, 36
term
receives the incoming call.
CM35 Y=15
CM76 Y=34,
36
CM15
Y=216
CM64 Y=10
CM35
Y=170-172
Continued on next page