NEC Univerge NEAX 2000 IPS Command Manual page 361

Internet protocol server
Hide thumbs Also See for Univerge NEAX 2000 IPS:
Table of Contents

Advertisement

COMMAND CODE TITLE:
31
Y
DATA
A
05
Backward signal meaning Pulse Form sig-
nal on DID MFC call
[Not used in North America]
06
Backward signal meaning Pulse Type-1 sig-
nal on DID MFC call
[Not used in North America]
07
Backward signal meaning Pulse Type-2 sig-
nal on DID MFC call
[Not used in North America]
14
Number of digits to be deleted from ANI
[North America Only]
NOTE 1:
Effective only when CM31 Y=A>05 is assigned.
NOTE 2:
Pulse Form/Pulse Type-1/Pulse Type-2 signals mean the signals to ignore incoming Forward
signals for a predetermined time when address is completed.
These signals are effective for the following Backward signals:
• Pulse Form signal: Backward GA-3 signal (Address complete, change over GB)
• Pulse Type-1 signal: Backward GA-4 signal (Congestion)
• Pulse Type-2 signal: Backward GA-6 signal (Address complete, set up speech condition)
MFC/MF-ANI TRUNK DATA
1ST DATA
MEANING
INITIAL
NOTE 1, NOTE 2
INITIAL
NOTE 1, NOTE 2
INITIAL
DATA
NONE
Pulse Form signal is sent immediately with-
out sending Backward GA-1 signal (Send
next digit)
NOTE 2
01
Backward GA-1 signal
15
Backward GA-15 signal
NONE
No data
01
Backward GA-1 signal
15
Backward GA-15 signal
NONE
No data
01
Backward GA-1 signal
15
Backward GA-15 signal
NONE
No digit deletion
00
No digit deletion
01
Leading one digit deletion
10
Leading 10 digit deletion
– 337 –
: Initial Data
2ND DATA
MEANING
Continued on next page
NWA-008844-001 Rev.5.0
CM31
91ch3003.fm

Advertisement

Table of Contents
loading