NEC Univerge NEAX 2000 IPS Command Manual page 424

Internet protocol server
Hide thumbs Also See for Univerge NEAX 2000 IPS:
Table of Contents

Advertisement

COMMAND CODE TITLE:
41
Y=1
1ST
Y
MEANING
DATA
Off-Hook Detect
00
Timer
DP Telephone On
Hook Detect Timer
01
PB Telephone On
Hook Detect Timer
02
DP Telephone Hook-
03
flash Breaker Timer
PB Telephone Hook-
04
flash Break Timer
1
Hookflash Make
05
Timer
Maximum Dial Break
06
Timer
Dial Interdigit Pause
07
Timer
Momentary Open/
Reverse Timer
08
Delayed Ringing
09
Timer
SYSTEM TIMER DATA
INITIAL
DATA
256
01 02 03 ........................................................ 15
ms.
128 256 384 ..................................................... 1920
1024
03
384 512 640 768 896 1024 ........................... 1920
1216
ms.
576 704 832 960 10881216 ............................2118
1024
03
384 512 640 768 896 1024 ........................... 1920
1216
ms.
576 704 832 960 10881216 ............................2118
384
01 02 03 ........................................................ 16
ms.
384 512 640 ..................................................... 2304
384
01 02 03 ........................................................ 16
ms.
384 512 640 ..................................................... 2306
128
01 02 03 ........................................................ 15
ms.
128 256 384 ..................................................... 1920
256
01 02 03 ........................................................ 15
ms.
64 96 128 ...................................................... 480
256
01 02 03
ms.
64 128 192
256
01 02 03 ........................................................ 10
128 256 384 ..................................................... 1280
384
ms.
256 384 512 ..................................................... 1408
10
01 02 03 ........................................................ 10
seconds
2
2ND DATA
TIMER
04 05 06 07 08 ............................... 15
04 05 06 07 08 ............................... 15
4
6 ......................................................... 20
– 400 –
CM41
INCREMENT
UNIT
128 ms.
128 ms.
128 ms.
128 ms.
128 ms.
128 ms.
32 ms.
64 ms.
128 ms.
2 seconds