COMMAND CODE TITLE:
DD10
DATA TABLE:
DATA
X00
Equipment Type for Port 0-3
X: Port 0-3 (0-3) for SMDR
X: Port 1/3 (1/3) for printer for PMS
X01
Data Speed for Port 0-3
X: Port 0-3 (0-3) for SMDR/MCI
X: Port 1/3 (1/3) for printer for PMS
X02
Stop Bit Length for Port 0-3
X: Port 0-3 (0-3) for SMDR
X: Port 1/3 (1/3) for printer for PMS
INTERFACE CONDITION FOR AP00 RS PORT
1ST DATA
FUNCTION
For SMDR
1 : SMDR terminal 0
2 : SMDR terminal 1
For printer for PMS
6 : External printer
For SMDR
1 : 300 bps
2 : 1200 bps
3 : 2400 bps
4 : 4800 bps
5 : 9600 bps
6 : 19200 bps
For MCI
1 : 300 bps
2 : 1200 bps
3 : 2400 bps
4 : 4800 bps
5 : 9600 bps
6 : 19200 bps
For printer for PMS
1 : 300 bps
2 : 1200 bps
3 : 2400 bps
4 : 4800 bps
5 : 9600 bps
For SMDR/printer for PMS
0 : 1 bit
1 : 1.5 bits
2 : 2 bits
– 874 –
CMDD10
AP00 INITIAL
: Initial Data
2ND DATA
Continued on next page
NWA-008844-001 Rev.5.0