COMMAND CODE TITLE:
31
Y
DATA
1
3
Number of received digits of ANI
signal from PSTN
2
0
AP number 0
3
AP number 3
NOTE:
MFC/MF-ANI TRUNK DATA
1ST DATA
MEANING
INITIAL
INITIAL
AP number (0-3) corresponds to
the AP numbers assigned by CM05
as shown below.
CM31 Y=2
CM05 Y=0
AP number 0: AP number X
AP number 1: AP number Y
AP number 2: AP number Z
AP number 3: AP number W
(X<Y<Z<W)
DATA
NONE
No data
01
1 digit
31
31 digits
0
Designation of MFC/MF Sender and
Receiver, Caller ID Receiver, Enhanced 911
3
Sender to each circuit (No. 0-3)
DATA
– 331 –
: Initial Data
2ND DATA
MEANING
SENDER
RECEIVER
0
No. 0-3
1
No. 0, 1
No. 2, 3
2
No. 2, 3
No. 0, 1
3
No. 0-3
Continued on next page