Specifying the Transmit Start Rate
aurora
agreed CIR using the following options. Specify the rate at
which to start testing - this is expressed as a bits per time
interval (b/tc) and can be equal to or below your CIR.
Highlight Tx Start Rate in the Variable Load Test
Config menu and press the RIGHT arrow key to
display the Tx Start Rate sub-menu.
Enter the transmit start rate - this value must be
within the given range or *CHECK RANGE* is
displayed.
Press ENTER to save and exit the sub-menu.
Specifying the Transmit End Rate
Specify the rate at which to stop testing - this is expressed as
a bits per time interval (b/tc) and can be equal to or above
your CIR.
Highlight Tx End Rate in the Variable Load Test
Config menu and press the RIGHT arrow key to
display the Tx End Rate sub-menu.
Enter the transmit start rate - this value must be
within the given range or *CHECK RANGE* is
displayed.
Press ENTER to save and exit the sub-menu.
Specifying the Transmit Interval
Use this option to define how much the load transmitted is
increased each time the transmit interval time has passed. For
example if the transmit interval is 1 kb and the transmit
interval time is 1 minute, the load increases by 1 kb/tc every
1 minute.
Highlight Tx Interval in the Variable Load Test
Config menu and press the RIGHT arrow key to
display the Tx Interval sub-menu.
5-84
Tempo
lets you test the boundaries above and below your