Including a CRC Value

You can switch the Cyclic Redundancy Check (CRC) line
encoding on or off on the line - to do this :
Highlight CRC and press ENTER or the RIGHT arrow
key to toggle between a tick ( ) and a cross ( ). When
a tick is displayed a CRC is included in the frame.

Selecting the Sealing Current

If aurora
current on or off. To do this:
Choose Sealing Current to display a sub-menu.
Highlight Normal or None, and press ENTER to save
your selection and exit the sub-menu.

Selecting Line Termination

At present only 100 ohms is available.
To place a resistance across the line:
Choose Termination to display a sub-menu of
resistances.
Highlight a resistance and press ENTER to save your
selection and exit the sub-menu.
For 75Ω termination, use the BNC connectors, for 120Ω
termination, use the RJ48C connector.