HP auroraTempo User Manual page 128

Table of Contents

Advertisement

aurora
Tempo
- User Guide
This window displays the following information:
Display
Total Frames
This is the total number of frames either transmitted or
received for the chosen DLCI since the start or reset of
statistics collection.
Frame Rate
This is the total number of frames either transmitted or
received per second - in other words, the throughput of
frames within one second.
Max Frm Size
Maximum Frame size - this is the maximum frame size either
transmitted or received for the chosen DLCI since the start
or reset of statistics collection.
Min Frm Size
Minimum Frame Size - this is the minimum frame size either
transmitted or received for the chosen DLCI since the start
or reset of statistics collection.
Total Octets
This is the total number of octets either transmitted or
received for the chosen DLCI since the start or reset of
statistics collection.
Bit Rate
This is the number of bits either transmitted or received
per second - in other words, the throughput of bits
within one second.
BECN Frames
This is the number of frames either transmitted or received
over the virtual circuit for the chosen DLCI which have
Backward Explicit Congestion Notification (BECN) bits set.
FECN Frames
This is the number of frames either transmitted or received
over the virtual circuit for the chosen DLCI which have
Forward Explicit Congestion Notification (FECN) bits set.
DE Frames
This is the number of frames either transmitted or received
over the virtual circuit for the chosen DLCI which have
Discard Eligible (DE) bits set.
Short Frames
This is the number of frames either transmitted or received
for the chosen DLCI whose length falls short of the specified
number of bytes.
5-48
Statistics
Description
423972