Routine Maintenance Procedures; Routine Maintenance Procedures For The Ptx5000 Packet Transport Router - Juniper PTX5000 Hardware Manual

Packet transport router
Hide thumbs Also See for PTX5000:
Table of Contents

Advertisement

CHAPTER 34

Routine Maintenance Procedures

Routine Maintenance Procedures for the PTX5000 Packet Transport Router

Purpose
Action
Related
Documentation
Copyright © 2017, Juniper Networks, Inc.
Routine Maintenance Procedures for the PTX5000 Packet Transport Router on page 479
For optimum performance, perform preventive maintenance procedures.
On a regular basis:
Inspect the installation site for moisture, loose wires or cables, and excessive dust.
Make sure that airflow is unobstructed around the packet transport router and into the
air intake vents.
Check the status-reporting devices on the craft interface: system alarms, LEDs, and
the craft interface display.
Inspect all air filters in the packet transport router for dust and debris.
As a general guideline, we recommended that you replace the filter elements every 6
months for routers operating in a typical environment. The filter elements degrade
over time, and replacement intervals will vary by operating environment.
NOTE:
Do not run the packet transport router for more than a few minutes
without all the air filters in place.
PTX5000 Craft Interface Description on page 16
Maintaining the PTX5000 Air Filters on page 482
479