Installing a PTX5000 Three-Phase Wye AC PDU

330

Figure 204: Removing a Three-Phase Wye AC PDU

To install a three-phase wye AC PDU:
Ensure that the voltage across the AC power source is 0 V and that there is no chance
1.
that the voltage might become active during installation.
Switch the circuit breaker on the PDU to the off (
2.
Grasping both the front and top installation handle, insert the replacement PDU into
3.
the PDU slot.
Using both hands, slide the PDU into the chassis until you feel resistance.
4.
Push the front installation handle up toward the PDU. Using a number 2 Phillips (+)
5.
screwdriver, tighten the captive screws on the handle.
) position.