Figure 235: 20-A Plug Type (North America) - Juniper PTX5000 Hardware Manual

Packet transport router
Hide thumbs Also See for PTX5000:
Table of Contents

Advertisement

Copyright © 2017, Juniper Networks, Inc.
Reinstall the PSMs into the PDU.
6.
Loosen the captive screws on the door covering the PSMs and open the door.
a.
Place one hand underneath the PSM to support it and slide it into the PSM slot.
b.
Push the ejector handle toward the PSM, and tighten the captive screw on the
c.
ejector handle to secure it to the PSM.
Repeat these steps for all the other PSMs in the PDU.
d.
Using a number 2 Phillips (+) screwdriver, loosen the two screws from the metal door
7.
of the metal AC wiring compartment located in the middle of the PDU for 20-A inputs
and lower part of the PDU for the 30-A inputs.
Using a number 2 Phillips (+) screwdriver, loosen the screw on the 20-A input terminal
8.
and plug in the connector.(see
in the connector.
NOTE:
The 30 A connector does not have a clamp, it has its own integral
clip for locking the connector.

Figure 235: 20-A Plug Type (North America)

Chapter 27: Removing and Installing Power System Components
Figure 236 on page
366). Tighten the screw after plugging
365