Action To Take After An Electrical Accident; Prevention Of Electrostatic Discharge Damage - Juniper PTX5000 Hardware Manual

Packet transport router
Hide thumbs Also See for PTX5000:
Table of Contents

Advertisement

Action to Take After an Electrical Accident

Related
Documentation

Prevention of Electrostatic Discharge Damage

Copyright © 2017, Juniper Networks, Inc.
If an electrical accident results in an injury, take the following actions in this order:
Use caution. Be aware of potentially hazardous conditions that could cause further
1.
injury.
Disconnect power from the device.
2.
If possible, send another person to get medical aid. Otherwise, assess the condition
3.
of the victim, then call for help.
General Safety Guidelines and Warnings on page 581
General Electrical Safety Guidelines and Warnings on page 609
AC Power Electrical Safety Guidelines
DC Power Electrical Safety Guidelines for Switches
Device components that are shipped in antistatic bags are sensitive to damage from
static electricity. Some components can be impaired by voltages as low as 30 V. You
can easily generate potentially damaging static voltages whenever you handle plastic
or foam packing material or if you move components across plastic or carpets. Observe
the following guidelines to minimize the potential for electrostatic discharge (ESD)
damage, which can cause intermittent or complete component failures:
Always use an ESD grounding strap when you are handling components that are subject
to ESD damage, and make sure that it is in direct contact with your skin.
If a grounding strap is not available, hold the component in its antistatic bag (see
Figure 315 on page
612) in one hand and touch the exposed, bare metal of the device
with the other hand immediately before inserting the component into the device.
WARNING:
For safety, periodically check the resistance value of the ESD
grounding strap. The measurement must be in the range 1 through
10 Mohms.
When handling any component that is subject to ESD damage and that is removed
from the device, make sure the equipment end of your ESD grounding strap is attached
to the ESD point on the chassis.
If no grounding strap is available, touch the exposed, bare metal of the device to ground
yourself before handling the component.
Chapter 46: Electrical Safety Guidelines and Warnings
611