PTX5000 Packet Transport Router Hardware Guide
50
Figure 31: AC Power Cord
1—
Retaining nut
High Capacity Wye AC PDU Components
Each High Capacity Wye AC PDU has the following components
A metal retaining bracket located on the lower right to connect the wye AC power cord
to the PDU.
A metal wiring compartment that contains the AC input terminal block and ground.
The AC terminal block consists of three input terminals labeled
to right. The neutral input is labeled
One 80-A circuit breaker.
The output power switch provides power to the power supply modules.
LEDs to monitor the status of the PDU.
NOTE:
The PDUs contain no fans, but are cooled by the fans in the power
supply modules.
1
2
2—
AC power cord
N
.
(Figure 32 on page
,
, and
, from left
L1
L2
L3
Copyright © 2017, Juniper Networks, Inc.
51):