Total Access 5000 Business Services Deployment Guide

Ethernet OAM on the NetVanta 800/8000 Series NCTE

To configure Ethernet OAM on the NetVanta 800/8000 Series NCTE, complete the following 
procedure:
1. Enable Ethernet OAM on the NetVanta 800/8000 Series NCTE.
2. Create the Ethernet OAM MD.
3. Within the newly created MD, create one or more Ethernet OAM Maintenance 
4. Create Maintenance End Points (MEP) and enable CCMs per MEP.
5. On products that support MIPs, edit the Default MD. 
C-4
The MD contains the following attributes:   
• Name
• Domain Level
Associations (MA).
The MA contains the following attributes:
• Name
• Component
• Component's Primary VID
• CCM Interval
• Associated Remote MEPs
The MEP contains the following attributes:
• MEPID
• Direction
• Interface
• Priority
• CCM Transmission State
The Default MD contains the following attributes:
• Default MIP Creation Rule
• Default MIP Level
• Component
• Component's Primary VID
• Component's MIP Creation Rule
• Component's MIP Level
65K510DEP08-1A