Remote Loopback; Figure O-3. Remote Loopback Diagram - ADTRAN Total Access 5000 Deployment Manual

Hide thumbs Also See for Total Access 5000:
Table of Contents

Advertisement

Total Access 5000 Business Services Deployment Guide

Remote Loopback

A remote loopback transmits a Far End Loop‐up code via the FEAC channel in the DS3 
module to the NetVanta 873, which responds by setting‐up a line loopback towards the DS3 
card in the Total Access 5000. After the NetVanta 873 DS3 port is looped‐up, Bit Error Rate 
Test (BERT) patterns can be sent from the DS3 card to test the integrity of the DS3 circuit.
NOTE
DS3 BERT patterns can be sent from external test equipment. For example,
the integrated BERT in the DS3 EFM module or the NetVanta 873 can be used
in place of an external DS3 test set.
The Remote Loopback request only works in the C‐Bit framing mode.
NetVanta 873
DS-3 Facility
O-4
Remote Loopback
Framer

Figure O-3. Remote Loopback Diagram

Total Access 5000
Framer
DS-3 Facility
65K510DEP08-1A