Provision the RPR Line Module Service State
The card service state must be set to IS.
NOTE
The RPR Line Modules work in a Master/Slave relationship. The active
(Master) must be IS, and the standby (Slave) must in the IS, Standby‐Hot (IS,
S‐H) state. If the modules are Out‐of‐Service, the span should be down and
the card should not participate in any redundancy or ring operation, nor
should it participate in database mirroring.
To set the card service state, complete the following procedure:
1. From the RPR Line Module menu, select Provisioning , and press E
65K510DEP08-1A
Appendix L, RPR Provisioning - Central Office Terminal (COT) Node Provisioning
TID: HSV00001
Unacknowledged Alarms: None
Figure L-3. RPR Line Module Main Menu
Figure L‐4 displays the RPR Line Module Provisioning menu.
Total Access 5000
System
RPR Line Module: Active
1. Configuration
2. Provisioning
3. Status
4. Test
5. Alarms
6. Performance Monitoring
7. Event Log
Selection :
'?' - System Help Screen
MM/DD/YY HH:MM
Unit Number:
1
NTER
.
L-5