Provision the Uplink Identifier
The uplink identifier settings are depdendant on the Nodes connection through the EFM card.
To set the uplink identifier for the COT, complete the following:
1. From the Provisioning menu, select EFM Setting , and press E
2. From the EFM Settings menu, select Uplink Identifier , and press E
3. From the Uplink Identifier System menu, select System , and press E
Provision the DS1 Interface
To provision the DS1 Interfaces, complete the following:
1. From the T1 8‐Port Main menu, select Provisioning , and press E
2. From the Provisioning menu, select DS1 Interfaces , and press E
3. From the DS1 Interface menu, select the required DS1, and press E
4. From the DS1 Port Provisioning menu, select Service State , and press E
5. From the Service State menu, select In Service , and press E
6. From the DS1 Port Provisioning menu, select Line Buildout , and press E
7. From the Output LBO menu, set the line buildout, and press E
8. From the Provisioning menu, select EFM Setting , and press E
9. From the EFM Setting menu, select DS1 Bonding , and press E
65K510DEP08-1A
Appendix J, GigE Star Provisioning - Central Office Terminal (COT) Provisioning
• None: When selected, this option does not set the timing source to the DS1. Timing
defaults to the timing set in the GigE SM.
This options used for provisioning both the cable length (in feet) and the transmit pulse
shape and attenuation applied to the transmit signal. Using the 0 dB setting provides for
the longest circuit length. The valid options are:
• 0 – 133 ft
• 133 – 266 ft
• 266 – 399 ft
• 399 – 533 ft
• 533 – 655 ft
• 0 dB
• –7.5 dB
• –15 dB
• –22.5 dB
NTER
.