Total Access 5000 Business Services Deployment Guide
Once completed and if the management VLANs of the GigE SM and the NetVanta 800 are
equivalent, the NetVanta 800 Command Line Interface (CLI) can be accessed via the Inband
Management VLAN.
Modify an Existing Bridge
There are two ways to modify an existing EFM bonding group. The EZ‐EFM application
allows the user to add or remove a link to/from a bonding group while simultaneously speci‐
fying the bonding group upstream and downstream data rates. The EZ‐EFM application
automatically re‐provisions all links in the group to the necessary link rates, whether the rate
is increased or decreased. The links retain and provide the provisioned data rate.
The second way to add or remove a link to/from a group is by directly modifying the EFM
bonding group in the EFM Bonding Group Configuration prompt. This method does not
result in a re‐provisioning of the links in the group, but can result in the links not being set to
the optimum rates, or even in the group not providing the specified data rate if links are
removed.
Modify a Bonding Group with EZ-EFM
To modify a bonding group using the EZ‐EFM application, complete the following:
1. From the Enable prompt, type application , and press E
2. From the Application Configuration prompt, type ez-efm 1 and press E
3. From the EFM Configuration prompt, type one of the following commands to modify an
4. From the EFM Configuration prompt, type one of the following commands to remove
NOTE
For the modify command, all parameters must be specified, even if a
particular value is not being changed.
6-10
Configuration prompt.
EZ Ethernet application.
existing EFM Bonding Group:
• To provision the DS3 EFM 4‐Port, type modify <group_name> link <slot/
port> upstream <0-250000> downstream <0-250000> active-links-
, and press E
minimum <1-n>
• To provision the DS3 EFM 3‐Port, type modify <group_name> link <slot/
port:channel> upstream <0-250000> downstream <0-250000> active-
links-minimum <1-n>
Refer to Table
6‐3 on page 6‐7 for the list of variables for the EFM bonding group.
links from an existing EFM Bonding Group:
• To provision the DS3 EFM 4‐Port, type modify <group_name> no-link <slot/
port> upstream <0-250000> downstream <0-250000> active-links-
, and press E
minimum <1-n>
• To provision the DS3 EFM 3‐Port, type modify <group_name> no-link <slot/
port:channel> upstream <0-250000> downstream <0-250000> active-
links-minimum <1-n>
NTER
.
, and press E
NTER
.
NTER
.
, and press E
NTER
.
NTER
to access the Application
NTER
to start the
65K510DEP08-1A