Figure M-2. Current Protection Menu - ADTRAN Total Access 5000 Deployment Manual

Hide thumbs Also See for Total Access 5000:
Table of Contents

Advertisement

4. From the Current Protection menu, press  E  or  W  to change the direction to East or West.
5. From the Current Protection menu, select the appropriate switch, and press  E
65K510DEP08-1A
Appendix M, Add/Remove Node from RPR Ring - Perform a Manual or Forced Switch
TID: TA5000
Unacknowledged Alarms: None
Current West Protection: Idle

Figure M-2. Current Protection Menu

The following options are available:
• Force Switch: This selection forces traffic away from the span, regardless of the ring 
state
• Manual Switch: This selection forces traffic away from the span, only when the ring 
is closed, with no errors
Total Access 5000 System
1. Force Switch
2. Manual Switch
3. Idle
Selection :
2
W-West
E-East
'?' - System Help Screen
MM/DD/YY hh:mm
Node:
1
.
NTER
M-3