3. Type end , and press Enter to return to the Enable prompt.
Provision the Network Ports
To configure the network port administration states, complete the following procedure:
NOTE
This is a single node setup, therefore Network Port 2 will be set to the Out of
Service‐Unassigned state. This prevents any unnecessary alarms for the
unused network port.
1. From the Enable prompt, type configure terminal , and press E
2. From the Global Configuration prompt, type interface gigabit-ethernet 1/A/1 ,
3. Type no shutdown , and press E
4. Type interface gigabit-ethernet 1/A/2 , and press E
5. Type shutdown , and press E
6. Type exit , and press E
7. Type interface gigabit-ethernet 1/B/1 , and press E
8. Type no shutdown , and press E
9. Type interface gigabit-ethernet 1/B/2 , and press E
10. Type shutdown , and press E
11. Type end , and press E
NOTE
The GigE SM NET 1 LED should be green. If not, perform physical layer
diagnostics.
65K510DEP08-1A
bal Configuration prompt.
and press E
to access the slot A, Net 1 Configuration prompt.
NTER
Configuration prompt.
NTER
Configuration prompt.
Configuration prompt.
NTER
Section 3, Common Provisioning - Provision the GigE SM
NTER
to set the port to In Service.
NTER
to set the port to Out of Service, Unassigned.
to return to the Global Configuration prompt.
NTER
to set the port to In Service.
NTER
to set the port to Out of Service, Unassigned.
to return to the Enable prompt.
NTER
to access the Glo‐
NTER
to access the slot A Net 2
NTER
to access the slot B, Net 1
NTER
to access the slot B, Net 2
3-7