Remote Loopback Configuration; Test Administrative Functions; Local Line Loopback Configuration; Bert Test Configuration - ADTRAN Total Access 5000 Deployment Manual

Hide thumbs Also See for Total Access 5000:
Table of Contents

Advertisement

Total Access 5000 Business Services Deployment Guide

Remote Loopback Configuration

To configure the unit to respond to (enable) or to ignore (disable) to remote loopback 
commands, complete the following steps:
1. From the Enable prompt, type  configure terminal , and press  E
2. From the Global Configuration prompt, type  interface t3 <shelf/slot/port> , and 
3. From the T3 Interface Configuration prompt, perform one of the following:
4. From the T3 Interface Configuration prompt, type  end , and press  E

Test Administrative Functions

The Total Access 5000 CLI Application prompt, controls both the local loopback and BERT 
functions. While in the Application prompt, the following commands can be issued:
• View the current test status of the DS3 interface by typing  show test interface t3
• Clear the test statistics of the DS3 interface by typing  test interface t3
• Stop any test in progress (loopback or BERT) by typing  no test interface t3

Local Line Loopback Configuration

To configure local DS3 loopbacks, complete the following steps:
1. From the Enable prompt, type  application , and press  E
2. From the Application prompt, type  test interface t3 <shelf/slot/port> local
NOTE
•  The loopback timeout is optional and can be left off the loopback command
NOTE
•  The DS3 line loopback can be stopped by typing  no test interface t3
<shelf/slot/port>

BERT Test Configuration

The Channelized DS3 Multi‐Service 3‐Port performs BERT generation and testing at the DS3 
interfaces. To configure the DS3 BERT, complete the following steps:
G-4
bal Configuration prompt.
press  E
NTER
 to access the T3 Interface Configuration prompt.
• Type remote-loopback , and press  E
loopback commands.
• Type  no remote-loopback , and press  E
loopback commands.
Enable prompt.
, and press  E
<shelf/slot/port>
<shelf/slot/port> clear
, and press  E
<shelf/slot/port>
prompt.
loopback line timeout <0-9999>
, and press  E
NTER
 to provision the port to respond to remote 
NTER
 to provision the port to ignore remote 
NTER
, and press  E
NTER
NTER
, and press  E
NTER
NTER
NTER
 to access the Glo‐
NTER
 to return to the 
NTER
 to access the Application 
 to start a DS3 line loopback.
65K510DEP08-1A

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ta 5000

Table of Contents