Create A Mip On A Vlan; Mip Creation Example; Create A Gigabit-Ethernet Mep On The Total Access 5000 - ADTRAN Total Access 5000 Deployment Manual

Hide thumbs Also See for Total Access 5000:
Table of Contents

Advertisement

Total Access 5000 Business Services Deployment Guide

Create a MIP on a VLAN

MIPs are created in the default domain per the MIP rules set per VLAN. For a VLAN to be 
added to the default domain, the EVC for the VLAN should be created before the following 
steps are performed.
Once the VLAN has been added to the default domain, create the MIP by performing the 
following steps:
1. From the Global Configuration prompt, type  ethernet cfm default-domain to enter 
2. From the Ethernet OAM Default Domain Configuration prompt, type  component 1
3. From the Ethernet OAM Default Domain Component Configuration prompt, type  level
4. Type  mip-allowed any  to allow MIPs to be created on the VLAN.
NOTE
The MIP is created at the lowest level between the level at which the domain
was created and the default domain level. The example commands above
created the domain at level 6, and the default domain was set to level 4, thus,
the MIP is created at level 4.

MIP Creation Example

 The following example displays an additional MIP created on VLAN 200.

Create a Gigabit-Ethernet MEP on the Total Access 5000

To create a network‐facing MEP at the Gigabit‐Ethernet network interface of the Total Access 
5000, complete the following (assumes the MD and MA has been created):
1. From the Global Configuration prompt, type  interface gigabit 1/<active_SM>/1  
2. From the Gigabit Ethernet Interface Configuration prompt, type  ethernet cfm mep
3. From the Ethernet OAM MEP Configuration prompt, type  no mep-shutdown  to enable 
4. From the Ethernet OAM MEP Configuration prompt, type  exit , and press  E
5. From the Gigabit Ethernet Interface Configuration prompt, type  exit , and press  E
C-12
the Default Domain Configuration prompt.
vlan <1-4094>
to enter the Component Configuration prompt.
<0-7>
to set the default level of the component.
Switch(config)#ethernet cfm default-domain
Switch(config-ecfm-def-domain)#component 1 vlan 200
Switch(config-ecfm-def-comp)#level 4
Switch(config-ecfm-def-comp)#mip-allowed any
to enter the Gigabit‐Ethernet Interface configuration.
<mepid> <domain_name> <domain_association> down
the MEP.
return to the Gigabit Ethernet  Interface Configuration prompt.
return to the Global Configuration prompt.
 to create the MEP.
NTER
 to 
NTER
65K510DEP08-1A
 to 

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ta 5000