LMIO2 High-Speed Rear Panel
The LMIO2 High Speed Rear Panel provides a high‐speed data path from a front panel SFP to
an adjacent GE 4‐Port, GE 8‐Port, or RPR Line Module.
In a packet ring configuration, the LMIO2 High‐Speed Rear Panel is used to provide a high
speed data link and handshake communications between two Total Access 5000 RPR Line
Modules. Both applications can also be used for automatic protection switching (APS).
LMIO2 DS3 BNC Rear Panel
The LMIO2 DS3 BNC Rear Panel is a series of I/O modules for the ATM DS3 Line Modules on
the rear of the Total Access 5000 chassis. The LMIO2 DS3 BNC Rear Panel provides Tx (out)
and Rx (in) BNC connectors for the ATM DS3.
NOTE
The LMIO2 DS3 BNC Rear Panel only supports the DS3 ATM Line Module.
Installing a DS3 BNC Rear Panel
To install the DS3 BNC Rear Panel, complete the following:
1. If installed, remove the rear blank panel.
2. Position the DS3 BNC Rear Panel on the rear alignment pins on the back of the Total
3. Using the 0.335 inch screws on the top and the 0.725 inch Captive Panel screw on the
4. Install the transmit and receive DS3 cables.
!
WARNING
To meet NEBS Level 3 and provide proper airflow and filtration, the
applicable rear panel must be installed in any occupied slot, and a front and
rear panel blank must be installed in any empty slots.
65K510DEP08-1A
Access 5000 Chassis.
bottom, secure the DS3 BNC Rear Panel to the chassis.
Section 2, Installation - Install and Connect the Rear Panel Components
2-13