Disable Unused Netvanta 800 Interfaces; Disable Unused Netvanta 800 Interfaces; Disable The Ds1 Interfaces - ADTRAN Total Access 5000 Deployment Manual

Hide thumbs Also See for Total Access 5000:
Table of Contents

Advertisement

Total Access 5000 Business Services Deployment Guide

Disable Unused NetVanta 800 Interfaces

The NetVanta 800 declares alarms for all unused interfaces (DS3, EFM, Ethernet, and Power 
Feed). To clear these alarms once the 800 is turned up, the appropriate interfaces must be shut 
down.
This section details the following information
• Disable the DS3 interfaces
• Disable the Ethernet interfaces
• Disable the Gigabit‐Ethernet interface
• Disable the power feed alarms
• Clear the alarm log

Disable the DS1 Interfaces

For each unused DS1 port in the EFM Bonding Group, complete the following:
NOTE
This must be done to clear the DS1 loss of signal and EFM near end sync
alarms.
1. From the Enable prompt, type  configure terminal , and press  E
2. From the Global Configuration prompt, access the unused DS3 portʹs configuration 
3. From the T3 Interface Configuration prompt, shut the DS3 port down by typing 
4. Repeat steps 2 to 3 for the remaining unused DS3 ports.
5. From the T3 Interface Configuration prompt, type  exit , and press  E
6. From the Global Configuration prompt, type  interface efm-group 1/0/1 , and press 
7. Remove the DS3 port from the bonding group by typing no link <slot/port> , and 
8. Repeat step 7 to remove all unused ports from the EFM bonding group.
9. Type  end , and press  E
Once all unused DS3 interfaces have been disabled, all DS3 and EFM bonding group alarms 
should be cleared in the alarm log, and the EFM LED should be lit solid green, if there are no 
other issues. Also, the partial EFM group alarm should clear.
6-28
bal Configuration prompt.
prompt by typing  interface t3 1/0/<port> , and press  E
, and press  E
shutdown
NTER
Global Configuration prompt.
E
 to access the EFM Bonding Group Configuration prompt.
NTER
press  E
. For NetVanta products, the slot is always zero.
NTER
NTER
.
 to return to the Enable prompt.
NTER
 to access the Glo‐
NTER
.
NTER
 to return to the 
65K510DEP08-1A

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ta 5000

Table of Contents