Total Access 5000 Business Services Deployment Guide
NOTE
The AMIO2‐CH50P supports the COMBO A2+ 24‐Port and RPOTS 24‐Port
Access Modules.
AMIO2-CH64P Rear Panel
The AMIO2‐CH64P covers two module slots on the rear of the Total Access 5000 Chassis. The
AMIO2‐CH64P is designed to hold two standard entry 64‐pin male champ connector cables.
For standard entry, the cable exits the 90° connector hood on the pin 1 end of the male champ
connector.
NOTE
Push‐through panels are provided with four Captive Champ Screws for
installation of two connectors to the panel. Use two screws for each connector,
one for the mounting bracket, the second to secure the connector to the panel.
The Captive Champ Screw provided with the cable must be replaced if it is
not a 0.35 inch screw.
LMIO2-CH64B Rear Panel
The LMIO2‐CH64B is an interconnect for two line module slots on the rear of the chassis. The
LMIO2‐CH64B module provides metallic access to 32 four‐wire circuits per access module
installed for a maximum of 32 four‐wire circuits. Two 64‐pin male 90° champ connectors
attach to the LMIO2‐CH64B, and provide connection and stabilization between modules in
the Total Access 5000 Chassis and external cable connections that use 64‐pin connectors. For
standard entry, the cable exits the 90° connector hood on the pin 1 end of the male champ
connector.
LMIO2-CH50D Rear Panel
The LMIO2‐CH50D is an interconnect for two line module slots on the rear of the Total Access
5000 Chassis. The LMIO2‐CH50D provides metallic access to 8 four‐wire circuits per access
module installed for a maximum of 16 four‐wire circuits. Two 50‐pin male 90° champ
connectors attach to the LMIO2‐CH50D, and provide connection and stabilization between
modules in the Total Access 5000 Chassis and external cable connections that use 50‐pin
connectors. For standard entry, the cable exits the 90° connector hood on the pin 1 end of the
male champ connector.
LMIO2 HD DS1 Rear Panel
The LMIO2 HD DS1 Rear Panel is an interconnect for two line module slots on the rear of the
Total Access 5000 Chassis. The LMIO2 HD DS1 provides metallic access to 32 four‐wire
circuits per access module. Four 2 mm connectors provide access to the DSX loops. The upper
connectors provide the transmit pair, and the lower connectors provide the receive pair.
2-12
65K510DEP08-1A