Enable Efm Bonding Protection; Enable Efm Bonding Protection; Table 4-7. Efm Bonding Protection - ADTRAN Total Access 5000 Deployment Manual

Hide thumbs Also See for Total Access 5000:
Table of Contents

Advertisement

Enable EFM Bonding Protection

This subsection details the following information:
• Definition of EFM Bonding Protection
• Steps for enabling EFM Bonding Protection
EFM Bonding Protection Definition
EFM Bonding Protection is a Layer 2 application used to protect traffic carried by those access 
modules that include an EFM Bonding Engine as part of their feature set. EFM Bonding 
Protection will not work for access modules that do not have this feature. The purpose of EFM 
Bonding is the protection of traffic going to and from a particular slot, and not the access 
module in that slot.
In an EFM Bonding Protection configuration, the Total Access 5000 EFM Protect Module is 
installed in a Total Access 5000 shelf. Once the module is installed, it must be configured so it 
can protect traffic going to and from a module in a specific slot. By creating an EFM Bonding 
Group, traffic to and from a group of slots/access modules can also be protected. As an added 
feature, EFM Bonding Protection also allows each of these groups and/or access modules 
within a group to have a priority assigned to the traffic going to and from that access module 
or group. For example, assume that all the access modules are being protected by the EFM 
Protect Module in slot 11. The access modules in slot 1 to 8 have their priority set to 1 (priority 
levels range from 1 to 32 where 32 is the highest priority), and those access modules in slots 17 
to 21 have a priority level of 10. If one of the access modules in slots 1 to 8 goes offline, their 
traffic will switch over to the EFM Protect Module. The traffic will continue to pass through 
the EFM Protect Module until the access module that went offline comes back online, or an 
access module in slots 17 to 21 goes offline. If that occurs, the EFM Protect Module will switch 
to the slot/access module with the higher priority.
An example of how this configuration could be used is displayed in Table 4‐7.
SLOT 1
SLOT 2
Ports
Ports
1‐27
1‐27
BG 1
1
2
BG 2
3
3
4
4
5
5
6
6
7
7
8
8
BG9
9
10
BG10
11
11
65K510DEP08-1A

Table 4-7. EFM Bonding Protection

SLOT 3
SLOT 4
SLOT 5
Ports
Ports
Ports
1‐27
1‐27
1‐27
1
1
1
2
2
2
BG 3
3
3
4
BG 4
4
5
5
BG 5
6
6
6
7
7
7
8
8
8
9
9
9
10
10
10
BG11
11
11
Section 4, EoCu Provisioning - Enable EFM Bonding Protection
SLOT 6
SLOT 7
Ports
Ports
1‐27
1‐27
1
1
2
2
3
3
4
4
5
5
BG 6
6
7
BG 7
8
8
9
9
10
10
11
11
SLOT 8
BG
Location
Ports
NCTE
1‐27
1‐27
1
NCTE1
Slot 1
2
NCTE2
Slot 2
3
NCTE3
Slot 3
4
NCTE4
Slot 4
5
NCTE5
Slot 5
6
NCTE6
Slot 6
7
NCTE7
Slot 7
BG 8
NCTE8
Slot 8
9
NCTE9
Slot 1
10
NCTE10
Slot 2
11
NCTE11
Slot 3
4-17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ta 5000

Table of Contents