Install the SCM
To install the SCM, complete the following procedure:
NOTE
The SMIO3 must be installed before installing the SCM.
1. Pull the ejector latches, located on the upper and lower left‐hand side of the SCM front
2. Hold the SCM by the front panel while supporting the bottom edge of the module with
3. Align the module edges to fit in the lower and upper guide grooves for the slot labeled
4. Slide the module into the module slot. Apply simultaneous thumb pressure at the top
5. Secure the SCM in place by rotating the ejector latches into the locked positions.
GigE SM Description
The GigE Switch Module (SM) provides network data aggregation for the Total Access 5000
system. The GigE SM switches Ethernet traffic from the SFP inputs to the Access Module slots.
The GigE SM controls common system functions and communication between access modules
and the SCM. The GigE SM interfaces to the high speed backplane through the SMIO3.
Install the GigE SM
To install the GigE SM, complete the following:
NOTE
The SMIO3 must be installed prior to installing the GigE SM.
1. Pull the ejector latches, located on the upper and lower left‐hand side of the GigE SM
2. Hold the GigE SM by the front panel while supporting the bottom edge of the module
3. Align the module edges to fit in the lower and upper guide grooves of the Switch
4. Slide the GigE SM approximately halfway into the module slot and insert the copper or
5. Continue sliding the GigE SM into the chassis, applying simultaneous pressure at the top
6. Secure the GigE SM in place by rotating the ejector latches into the locked positions.
7. Connect the copper or optical cables with the appropriate connector that matches the
65K510DEP08-1A
panel, from the closed positions.
the ejector latches opened to engage the chassis edges.
12/SCM
.
and bottom of the module (to the right of the ejector latches) to ensure that the module is
firmly seated against the backplane of the chassis.
front panel, from the closed positions.
with the ejector latches opened to engage the chassis edges.
Module slot labeled SM A or SM B .
optical cable into the SFP module.
and bottom of the module (to the right of the ejector latches) to ensure that the module is
firmly seated against the backplane of the chassis.
SFP.