7. From the System‐Timing Configuration prompt, type  source primary external
8. From the System‐Timing Configuration prompt, type  exit , and press  E
9. If necessary, repeat steps 3 ‐ 6, replacing primary with secondary, for a secondary 

System Timing Configuration for Remote Terminal Node

To configure the system timing for the Remote Terminal Node, complete the following:
1. Log on to the Remote Terminal Node.
2. From the Enable prompt, type  configure terminal , and press  E
3. From the Global Configuration prompt, type  system-timing 1 , and press  E
4. From the System‐Timing Configuration prompt, type  source primary interface
5. From the System‐Timing Configuration prompt, type  source secondary interface
6. From the System‐Timing Configuration prompt, type  revertive hop-count , and 
7. From the System‐Timing Configuration prompt, type  exit , and press  E