Total Access 5000 Business Services Deployment Guide
to a Total Access 5000 Switch Module. Small Form‐factor Pluggable (SFP) cages are provided
for inputs on the front panel of each module for maximum flexibility of the interfaces.
!
CAUTION
Due to compliance certification requirements, only SFPs supplied by
ADTRAN can be used with the GE 4‐Port Line Module. ADTRAN cannot
certify system integrity with other SFPs.
NOTE
• A LMIO2‐CH64B must be installed prior to installing the GE 4‐Port Line
Module.
• For redundant configuration, the Total Access 5000 LMIO2 Rear Panel must
be installed prior to installing the GE 4‐Port Line Module. In a non‐
redundant configuration, the Total Access 5000 I/O Blank Panel must be
installed prior to installing the GE 4‐Port Line Module.
RPR Line Module Description
The RPR Line Module provides an optical ring transport option for the Total Access 5000.
The RPR Line Module provides uplink and downlink connectivity for the Total Access 5000
by way of a fiber ring. An RPR ring provides the same type of Class of Service (CoS)‐aware
connectivity as other uplink and downlink ports in the Total Access 5000 network, and
supports transport of all Total Access 5000 services, signaling, and timing to other Total Access
5000s stationed on the ring.
The RPR Line Modules work in pairs, with each Line Module providing either an East or a
West span interface. The pair of RPR Line Modules should be in adjacent slots of the chassis,
with the lower, odd numbered slot providing the West interface, and the higher, even
numbered slot providing the East interface.
!
CAUTION
Due to compliance certification requirements, only 3.125 Gbps SFPs supplied
by ADTRAN are to be used with the RPR Line Module. ADTRAN cannot
certify system integrity with other SFPs.
NOTE
The LMIO2 Rear Panel must be installed in the slots on the back of the Total
Access 5000 Chassis that correspond to the slots in which the RPR Line
Modules will be installed; the LMIO2 must be installed prior to installing any
RPR Line Module.
Prior to installing the RPR Line Module, install an ADTRAN approved optical SFP module
into the required SFP port. The SFP must be capable of running at 3.125 Gbps line rate to
support a 2.5 Gbps data rate.
2-22
65K510DEP08-1A