Total Access 5000 Business Services Deployment Guide
Provision the Timing Source
To provision the timing source, complete the following:
1. From the Enable prompt, type configure terminal , and press E
2. From the Global Configuration prompt, type system-timing <shelf> , and press
3. From the System‐Timing Configuration prompt, type source primary loop-a
4. From the System‐Timing Configuration prompt, type source secondary loop-b
NOTE
ADTRAN recommends having the primary and secondary timing sources on
different DS3 ports and adjacent redundant slots.
Provision the T1 8-Port Line Module
This subsection details the following information:
• T1 8‐Port Line Module Provisioning Defaults
• Access the T1 8‐Port Line Module
• Provision the T1 8‐Port Line Module Service State
• Provision the T1 8‐Port Access Line Module DS1 Interface Service State
• Provision the Uplink Identifier
• Provision the DS1 Interface
T1 8-Port Line Module Provisioning Defaults
When the T1 8‐Port Line Module is installed in a Total Access 5000 shelf, the SCM queries the
system (local and clustered shelves) to synchronize its database. No user intervention is
required for this process. Provisioning is handled without user entry if Auto‐Provisioning is
enabled. Otherwise, provisioning must be accomplished manually through the SCM menu
system.
Table J‐4 shows the minimum list of factory defaults and values that are loaded after instal‐
lation and self‐test. These defaults and values provide the minimum configuration for turn up
of the T1 8‐Port Line Module.
J-6
bal Configuration prompt.
E
NTER
.
interface t3 <shelf/slot/port>
interface t3 <shelf/slot/port>
, and press E
.
NTER
, and press E
NTER
.
NTER
to access the Glo‐
65K510DEP08-1A