Provision the Line Module

This section details provisioning for the following modules:
• CH DS3 PPP/MLPPP 3‐Port Line Module
• DS1 PPP/MLPPP 32‐Port Line Module
Provision the CH DS3 PPP/MLPPP 3-Port Line Module
Administration Status
The CH DS3 PPP/MLPPP 3‐Port Line Module card service state must be set to In Service, Out 
of Service, or Out of Service‐Maintenance.
NOTE
•  If the card service state is set to Out of Service‐Maintenance, normal
operation occurs but alarms are not reported.
•  Line code and line buildout cannot be provisioned for either the DS3 or
DS1.
For traffic to pass, the CH DS3 PPP/MLPPP 3‐Port Line Module must be enabled.
Table 5‐2 displays the three administration states and shows the equivalent Service State from 
prior releases.
Command
no shutdown
shutdown maintenance
shutdown
To set the module administration and port administration states, complete the following 
procedure:
1. From the Enable prompt, type  configure terminal , and press  E
NOTE
If connected to the shelf where the module resides, the shelf number is
typically 1.
5-4

Table 5-2. Line Module Administration States

bal Configuration prompt.
Previous
Description
In Service
In the
and alarms are generated.
Out of Service, 
In the 
Maintenance
but no alarms are generated. Alarms are 
suppressed and no evidence of the alarm 
is shown.
Out of Service, 
In the
Unassigned
passes and no alarms are generated.
no shutdown
 state, traffic passes 
no shutdown
 state, traffic passes 
no shutdown
 state, no traffic 
NTER
 to access the Glo‐
65K510DEP08-1A