Total Access 5000 Business Services Deployment Guide
Provision the Line Module
This section details provisioning for the following modules:
• CH DS3 PPP/MLPPP 3‐Port Line Module
• DS1 PPP/MLPPP 32‐Port Line Module
Provision the CH DS3 PPP/MLPPP 3-Port Line Module
Administration Status
The CH DS3 PPP/MLPPP 3‐Port Line Module card service state must be set to In Service, Out
of Service, or Out of Service‐Maintenance.
NOTE
• If the card service state is set to Out of Service‐Maintenance, normal
operation occurs but alarms are not reported.
• Line code and line buildout cannot be provisioned for either the DS3 or
DS1.
For traffic to pass, the CH DS3 PPP/MLPPP 3‐Port Line Module must be enabled.
Table 5‐2 displays the three administration states and shows the equivalent Service State from
prior releases.
Command
no shutdown
shutdown maintenance
shutdown
To set the module administration and port administration states, complete the following
procedure:
1. From the Enable prompt, type configure terminal , and press E
NOTE
If connected to the shelf where the module resides, the shelf number is
typically 1.
5-4
Table 5-2. Line Module Administration States
bal Configuration prompt.
Previous
Description
In Service
In the
and alarms are generated.
Out of Service,
In the
Maintenance
but no alarms are generated. Alarms are
suppressed and no evidence of the alarm
is shown.
Out of Service,
In the
Unassigned
passes and no alarms are generated.
no shutdown
state, traffic passes
no shutdown
state, traffic passes
no shutdown
state, no traffic
NTER
to access the Glo‐