Gigabit Ethernet 8-Port Line Module Description; Ds1 Ppp/Mlppp 32-Port Line Module Description - ADTRAN Total Access 5000 Deployment Manual

Hide thumbs Also See for Total Access 5000:
Table of Contents

Advertisement

NOTE
The RPR Line Module in the higher numbered slot is designated as the East
interface and the lower numbered slot is designated as the West interface.

Gigabit Ethernet 8-Port Line Module Description

The Gigabit Ethernet 8‐Port Line Module (GE 8‐Port LM) provides the EoF solutions similar to 
the EoCu and EoTDM . The GE 8 Port LM allows subtending of network channel termination 
equipment (NCTE) to provide Business Ethernet services. The GE 8 Port LM interfaces to the 
SM GigE on the Total Access 5000 shelf backplane to provide 1G, 2.5G and 5G bandwidth.
The GE 8 Port LM can be deployed in a redundant configuration through the use of a Total 
Access 5000 LMIO2 High Speed Rear Panel. The LMIO2 panel provides a control path 
between the redundant modules.
When the GE 8Port LM is used for redundant applications, the GE 8]Port LMs must be 
installed in adjacent slots with the left most GE 8 Port LM in an odd numbered slot (e.g.,  1  and 
2
,  21  and  22 ).
The GE 8 Port LM has eight front panel SFP cages that provide inputs for maximum interface 
flexibility.
The GE 8 Port LM can receive timing from the SM GigE via the backplane, and transmit this 
timing out of any of the eight faceplate ports using the Sync E format. The module will not 
receive timing on any of its faceplate ports.
NOTE
When using the GE 8‐Port LM to route data to an adjacent GE 8‐Port LM, an
LMIO2 High Speed Rear Panel must be installed prior to insertion of the GE
8‐Port LM into the Total Access 5000 Chassis.

DS1 PPP/MLPPP 32-Port Line Module Description

The DS1 PPP/MLPPP 32‐Port Line Module (DS1 PPP/MLPPP 32‐Port) provides 32 DS1 lines 
and supports Point‐to‐Point and Multi‐Link Point‐to‐Point protocols. The 32 DS1s are 
intended for in‐plant use and have no fuse or lightning protection.
NOTE
•  The DS1 PPP/MLPPP 32‐Port can be installed in any slot (excluding slots
labeled 11, 12/SCM, SM A, and SM B) of the Total Access 5000 Chassis. If
installing only one DS1 PPP/MLPPP, it is recommended that it be installed
in an odd slot.
•  Prior to installing the DS1 PPP/MLPPP 32‐Port, install a Line Module
Input/Output Dual HD DS1 Divided Pair Rear Panel or a Line Module
Input/Output Dual Champ 64‐Pin Bridged Rear Panel.
65K510DEP08-1A
Section 2, Installation - Install the Front Panel Modules
2-23

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ta 5000

Table of Contents