Using the Equipment
3.9.3.7

Environment Alarms

Figure 3.29 Alarm Settings for Environment Section
Environment
3-52
Decoder error on 422 card (relay mapping) – Place a check mark in the box
to activate relay mapping for Decoder error on 422 card error.
Code version error on 422 card – Select the alarm condition from the drop-
down menu to be activated when the code version loaded on the 4:2:2 Decoder
Option card is not compatible with the motherboard code version. For the 3
Generation 4:2:2 Decoder Option card, the minimum supported code version is
3.0.
Code version error on 422 card (relay mapping) – Place a check mark in the
box to activate relay mapping for Code version error on 422 card error.
Over Temperature – Select the alarm condition from the drop-down menu to be
activated when an internal temperature value, set below, is exceeded (Set
Alarm /No Alarm).
Temp (Max Value) – Enter the maximum allowable internal temperature value
(degrees Centigrade). This is used to trigger the alarm condition, set above,
when exceeded.
OverTemperature (relay mapping) – Place a check mark in the box to activate
relay mapping for an overtemperature condition.
Fan 1/2/3/4 Failed – Select the alarm condition from the drop-down menu to be
activated when the fan speed is zero (Set Alarm /No Alarm).
Fan 1/2/3/4 Failed (relay mapping) – Place a check mark in the box to activate
relay mapping for fan 1/2/3/4 failure.