Splice Pid; User Pid - Ericsson RX8000 Reference Manual

Integrated receivers/decoders
Hide thumbs Also See for RX8000:
Table of Contents

Advertisement

Figure 3.149 Decode > Splice Section in Web Page
3.17.4.6.1

Splice PID

The Splice PID field provides the PID selection. The Splice PIDs are automatically
assigned when a service is selected and is based on their order within the service
PMT. This field provides an opportunity for the user to override any PID selections.
The NO SELECTION option allows the user to clear any PID selection and stop
Splice processing. Depending on the state of the PMT Update Mode selected from
the Decode > Advanced > Selection Control section, this setting may be
automatically overridden by the RX8000 after a PMT update event.
Also provided is the option to select a USER PID that has been defined in the
Decoder > Splice section. This allows the user to process any splice stream that
has not been declared in the PMT of the selected decode service. However, the
decoder will continue to enforce synchronization with the Program Clock Reference
(PCR) identified in the service PMT. If synchronization fails, this will disrupt the
splice processing.
3.17.4.6.2

User PID

The User PID field specifies the User PID value for Splice processing. The field
accepts PID values between 0 and 8191. The User PID is selected from the main
Splice PID selection list.
EN/LZT 790 0005 R7A