Using the Equipment
3.9.2.3.1

Control 1/2

Note: If the IP address of Control 1 and Control 2 are set to the same value, the
3.9.2.3.2
Common
3.9.2.3.3

Network Time Update

The implemented Simple Network Time Protocol (SNTP) client is able to
synchronize the system time with second tier NTP servers.
Configuration is only possible via the web browser interface on the page Device
Info > Network Settings.
Notes: If the SNTP interface is not being used, its associated alarm should be
3-36
IP – The IP address of this control port.
Subnet – The Subnet address of this control port.
Link Config – The link speed of the control port. This can be:
-
10 BaseT
-
10 BaseT Half Duplex
-
100 BaseT
-
100 BaseT Half Duplex
-
Auto
MAC Address – Displays the MAC address assigned to this control port (non-
editable).
Link Status – Displays the operating speed and mode of the established
Control link (e.g. 100 Mb Full Duplex).
MAC Address of Control 2 will be automatically adjusted to match that of
Control 1.
Gateway – The Gateway address common for both networks (Control 1 and 2).
Network Time Update – ON/OFF.
Time Zone – GMT + 12.
Daylight Saving – ON/OFF.
NTP Server No 1 – IP Address.
NTP Server No 2 – IP Address.
NTP Server No 3 – IP Address.
NTP Server No 4 – IP Address.
masked.
If the input stream contains TDT, this will override the NTP server derived
time.