3.17.4.7
Setup: Alarms > Relay Configuration
3.17.4.7.1
Relay Configuration
This field displays the options available for how to configure the behavior of the
three relays. It is located under the main Alarm tab only if the satellite input card
(DVB-S/S2) is fitted otherwise the control is hidden.
3.17.4.8

Setup: Save/Load

3.17.4.8.1
Save Splice Logs File
Figure 3.150 Save Splice Log File
Each time a splice event occurs whether it processed or ignored, these are logged
and can be accessed through the web browser interface under the main Save/Load
tab. The user can click on the link Right Click to Save to view the logs directly or as
suggested by the link, right-click over the link to download and save as a text file.
EN/LZT 790 0005 R7A
Summary Alarm; SCTE 35 Signalling: This is the default assignment for the
three relays. Relays 2 and 3 are used for signalling SCTE 35 splice events.
Relay Set
Relay 1
Relay 2
Relay 3
Summary Alarm; C/N Margin Alarm: This option is exposed only when the
satellite input card (DVB-S/S2) is fitted. This option allows the user to assign the
C/N Margin Alarm to a dedicated relay.
Relay Set
Relay 1
Relay 2
Relay 3
Purpose
Summary Alarm
SCTE 35 Control
Purpose
Summary Alarm
Not used
C/N Margin Alarm
Using the Equipment