Relay Assignments For Scte 35 Control; Conversion To Scte 104; Setup: Decode - Splice - Ericsson RX8000 Reference Manual

Integrated receivers/decoders
Hide thumbs Also See for RX8000:
Table of Contents

Advertisement

Using the Equipment
Only one splice event is processed at a time, the RX8000 is not designed to handle
multiple splice messages signaling multiple events. If a splice event has been
signaled then the RX8000 will only accept splice messages tagged with the same
Splice Event ID as the current event until the current event is either cancelled or
expired.
3.17.4.5.2

Relay Assignments for SCTE 35 Control

By default, the RX8000 relays are assigned to the Summary Alarm and SCTE 35
Control:
Table 3.51 Relay Pin Assignment for SCTE 35 Control
Relay Set Purpose
Relay 1
Relay 2
Relay 3
Note: If the satellite input card (DVB-S/S2) is fitted, the relay assignment can be
3.17.4.5.3

Conversion to SCTE 104

For units supporting HD-SDI output, SCTE 35 messages can also be converted into
SCTE 104 messages inserted in line 10 of the VANC space using DID 0x41 and
SDID 0x07. This feature is enabled using the Splice Insertion tick box and a count
of the spice points inserted is recorded in the Splice Count field.
Notes: Only the supported Splice messages specified above will be inserted in to
3.17.4.6
Setup: Decode > Splice
The basic selection and status information for Splice control can be found in the
Decode > Splice sub tab found within the Service section of the main Decode tab.
3-316
Summary Alarm
SCTE 35 Control: Splice
network In Point
SCTE 35 Control: Splice
network Out Point
manually configured for another purpose. Check that the Relay
Configuration mode found under the main Alarm tab is configured correctly
for SCTE 35 operation.
the VANC space.
SCTE 104 conversion requires the RX8200/HWO/HD or
RX8200/HWO/HD/3G option, so is not supported on the RX83XX IRD
range.
Pin
Pin Assignment
4
Common
8
Normally Closed (Closed on Alarm)
9
Normally Open (Open on Alarm)
2
Common
6
Normally Closed
7
Normally Open
1
Normally Closed
3
Common pin
5
Normally Open
EN/LZT 790 0005 R7A

Advertisement

Table of Contents
loading