Using the Equipment
3.11.2.9
Front Panel Setup
3.11.2.9.1

CI Module Status

This menu displays the presence of the CI Module (CAM), this will show either
PRESENT or NOT PRESENT, when diagnosing CI issues please check this menu
first, if the CAM has a fault it may not be detected by the unit.
3.11.2.9.2

CI Module Name

This menu displays the name of the CI module (CAM). This is a text string supplied
by the CA vendor and can be any value.
3.11.2.9.3

CI Forced Voltage 3V3

This menu allows the user to override the 3V3 / 5V sense for the CAM. Some CAMs
may be incapable of working correctly with 5V despite being advertised supporting
5V. This control forces the unit to supply only 3.3V to the CAM.
3.11.3

BISS

3.11.3.1
Availability
 = Option
BISS
BISS/MSD
3-146
MAX PIDS – In this case, the RX8000 has found more components that are
scrambled than are allowed by the configuration of the unit (Maximum CAM
Components). This may not be a problem but does mean that some of the
components scrambled within the service cannot be de-scrambled because of
limitations of the CAM.
CI
5.4.1
CI
5.4.2
CI
5.4.3
B = Supplied with Base Model
B
B
|CI MODULE STATUS
|PRESENT
|CI MODULE NAME
|VIACCESS
|CI VOLTAGE FORCED 3V3
|FALSE
B
B
EN/LZT 790 0005 R7A