Using the Equipment
3.18.4.6.2

Filter Status

Note: The Search Minimum Bitrate function will affect the TS Output Constant
3.18.4.6.3

IP Out 1 (and IP Out 2)

Figure 3.160 Output Tab > IP Out 1 Section
3-346
Pass Through EIT tables – By default EIT tables are not present in the filtered
Transport Stream. This tick box allows EIT tables to be passed through from the
input to the output stream.
Search Minimum Bitrate – This button initiates a simple search for the lowest
bit rate over a sample period of approximately one minute. The search will step
through a range of bit rate settings from 1 to 200 Mbps. During this time the
"Bitrate Search ACTIVE" alarm is raised and cleared once the search is
complete. Other alarms related to Service Filtering may be raised and cleared
during this time. Status information is updated to the right of the button and is
updated by pressing the Refresh button on the top-left of the page.
Bitrate control and therefore the bit rate of the filtered transport stream
being output on a live system.
Minimum Bitrate Reached – This field is updated after the bit rate search is
complete and holds the minimum bit rate found during the sample period which
did not cause any filter alarms.
Filter Buffer Level – This indicates the current level of the filter buffer as a
percentage value when the Service Filter Mode is active.
TX Enable – Checking this box enables the output on the 1
IP Output Card.
IP – This is the IP address of the 1
Subnet – Enables input of the Subnet mask address.
st
nd
/2
interface of the IP Output Card.
st
nd
/2
interface of the