This field displays a counter for the number of splice packets parsed by RX8000.
The counter rolls back to zero after the value 65535.
3.17.4.6.7

Cancel Active Splice

This button causes any active or pending Splice event to be cancelled, returning the
status to IDLE.
3.17.4.6.8

Event ID Filter

This field enables or disables Splice Event ID filtering according to the Event ID
Mask and Event ID Value settings. Event filtering allows operators to specify
different splice points for different units. Splice Event ID filtering effects relay
behavior only, it will not filter SCTE 104 messages.
When Event ID filtering is enabled, then the Event ID field extracted from every
SCTE 35 message is evaluated against a filter mask and if the result is true then the
SCTE 35 message will trigger the appropriate relay. When Event ID filtering is
disabled, all SCTE 35 messages will trigger the appropriate relay.
Event ID filtering is evaluated by determining the two results A and B as described in
Table 3.x below. If result A is equal to result B then this would allow the SCTE 35
message to pass the filter.
Table 3.52 Event ID Evaluation
Result
A
B
In the examples shown above, the value of result A (0000 1000) is equal to the
value in result B (0000 1000) and therefore this would trigger the relay.
EN/LZT 790 0005 R7A
Evaluation Description
The Event ID from the SCTE 35 message is evaluated against the
Event ID Mask using a logical-AND operator.
For example:
Event ID
Event ID Mask
Result A
The Event ID Value specified by the user is evaluated against the
Event ID Mask using the logical-AND operator.
For example:
Event ID Value
Event ID Mask
Result B
0000 1200 (hex) &
1000 1000 (hex) =
0000 1000 (hex)
0000 1000 (hex) &
1000 1000 (hex) =
0000 1000 (hex)