Using the Equipment
3.10.6.8.10

Packet Length Control and Packet Length Size

This menu allows the user to control manual packet length and its size.
Use the  (Forward) and  (Back) keys to move between manual packet length
and packet length size then use the  (Up)  (Down) keys to select the required
value from the available options, for manual packet length control:
For packet length size:
3.10.6.8.11

ATM Delta and Alpha

This menu allows the user to control Reed-Solomon and input de-randomiser.
Use the  (Forward) and  (Back) keys to move between ATM delta and ATM
alpha then use the  (Up)  (Down) keys to select the required value from the
available options within the range 0 – 0xff.
3.10.6.8.12

ATM Descrambler and ATM header correction

This menu allows the user to control the ATM descrambler and ATM header
correction.
Use the  (Forward) and  (Back) keys to move between ATM descrambing and
ATM header correction then use the  (Up)  (Down) keys to select the required
value from the available options.