Using the Equipment
3.17.5.4.4

Setup: SCTE 104 Output

Activate Splice Insertion, see section 0 This field allows the user to specify a 32-bit
hexadecimal value for the Event ID Value.
See the above section describing the Event ID Filter operation.
Splice Insertion.
Set SCTE 104 Insertion for HD or SD output, see section 3.17.4.6.12 SCTE 104
Insertion.
Optionally set Clamp Pre-roll, see section 3.17.4.6.13 Clamp Pre-Roll.
3.17.5.4.5

Setup: Relay Trigger

Optionally configure the relay to trigger on the splice event, see section 3.17.4.7
Setup: Alarms > Relay Configuration.
3.17.5.4.6

Setup: SCTE 35 Output

Configure the Output > Filter > Service Filter Mode to be set to either MULTI
SERVICE or REMAP. See section 3.19.3 Multi Service Filtering or 3.19.4
Remapping respectively, for detailed configuration of these modes.
3-324
DPI PID Index – The DPI PID index field to be used in SCTE 104.
Input Pre-roll – This is the pre-roll of the tones in the source. It is the time
between the end of the last tone of the sequence and when the splice is due.
Action – The type of splice message to send:
Start – This will send a splice_insert_type of spliceStart_normal for
-
SCTE 104. For SCTE 35 it will send a splice_insert command with the
out_of_network_indicator indicating an opportunity to exit from the network
feed, a Program Out Point.
End – This will send a splice_insert_type of spliceEnd_normal for
-
SCTE 104. For SCTE 35 it will send a splice_insert command with the
out_of_network_indicator indicating an opportunity to return to the
network feed, a Program In Point.
Auto Return – This will set the auto_return_flag and break_duration fields in
SCTE 104. This will insert a break_duration field in SCTE 35. This should be
used in conjunction with the Duration field.
Duration – Used in conjunction with the Auto Return field to define the duration
of the splice. Inserted in the break_duration field of the SCTE 104 and SCTE 35
message.
SCTE 104 – If enabled this will output a SCTE 104 packet with this event.
SCTE 35 – If enabled this will output a SCTE 35 packet with this event.
EN/LZT 790 0005 R7A