2.1

Read This First!

Please refer to the Installation, Safety and Compliance Information for Ericsson
Compression Products Reference Guide supplied with your product for full details of
installation requirements. This guide only contains additional product specific
information where required.
2.2

Mounting and Ventilation

2.2.1

Fixing and Rack Mounting

The equipment is designed for fixed use only and has been shipped with fixing
brackets suitable for a standard 19-inch rack. When installed in a rack, it should be
secured using the fixing brackets. In addition, support shelves must be used to
reduce the weight on the brackets. Ensure it is firmly and safely located and it has
an adequate flow of free-air.
Slide the receiver onto the chassis supports and affix to the rack by means of an
M6 x 18 mm Pan Head screw in each corner.
A freestanding unit should be installed on a secure horizontal surface where it is
unlikely to be knocked or its connectors and leads disturbed.
2.2.2
Ventilation
2.2.2.1

Openings in the Covers

Side openings in the unit, as well as side-mounted cooling fans, are provided for
ventilation. They ensure reliable operation of the product and protect it from
overheating. The openings of the fans must not be blocked or covered.
Figure 2.1 Air-flow through the Equipment
EN/LZT 790 0005 R7A
Fans are
mounted on
this side of
the unit
Installing the Equipment
Air is released
through vents
at the side of
the unit
2-3