Fault Codes
Faul t Code C harts
Fault Code Chart
Fault Code
Programmer
Diagnostic Display
Fault code LED
COMMUNICATION
is off or is on, but
ERROR
not blinking
1
12
HW FAILSAFE 1-2-3
13
M- SHORTED
FIELD OPEN
ARM SENSOR
FLD SENSOR
62
Condition
Machine will not drive.
Normal operation.
Machine will not drive.
Machine will not drive.
Machine will not drive.
Machine will not drive.
Machine will not drive.
Z®-45/25 Bi-Energy • Z®-45/25J Bi-Energy
Possible Causes
Solution
The key switch or
Push in the ground
Emergency Stop
control red Emergency
button(s) was cycled
Stop button to the off
on and off faster than 5
position and wait for 5
seconds OR controller
seconds. Pull out the
sensed an internal
ground control red
error during start up.
Emergency Stop
button to the on
position. If problem
persists, replace the
motor controller.
The motor controller
Replace the motor
failed self test.
controller.
The motor controller
Test the motor
has a internal short
controller. See Repair
between M- and B-
Section.
terminals.
Motor wiring is loose
Check for loose or
OR motor is defective
open connections at
OR motor controller
the drive motors and
has an internal short.
motor controller OR
replace the defective
drive motor OR test the
motor controller. See
Repair Section.
Defective motor
Replace the motor
controller.
controller.
Defective motor
Replace the motor
controller.
controller.
Part No. 1268546GT
September 2016