Fault Code Source - Genie ZX-135/70 Service And Repair Manual

Hide thumbs Also See for ZX-135/70:
Table of Contents

Advertisement

Service and Repair Manual
Fault Codes
Fault Source and Type will display as:
Source
" ID XXX_xx FAULT "
Where XXX is the one to three digit Fault Source
and xx is the two digit Fault Type.
TCON - Turntable Controller
PCON - Platform Controller
SCON - Safety Controller
DCON - Drive Controller
Fault Type
ID
Description
11
Value at 5V
12
Value too High
13
No Response
15
Value too Low
16
Value at 0V
17
Not Calibrated
21
Fault
26
Timeout
31
Invalid Setup
32
Min Cal Too Low
33
Min Cal Too High
156
Type
ZX®-135/70
Fault Source
ID
Description
3
SCON Controller Area Network
4
Primary Boom Angle Zone
5
Primary Boom Length Switches Cross-Check
8
PCON Controller Area Network
9
Engine
18
DCON Controller Area Network
20
Boom Extend/Retract Joystick
21
Boom Up/Down Joystick
26
Boom Extend/Retract Buttons
27
Boom Up/Down Buttons
28
Boom Angle Sensors Cross-Check (SCON)
29
LSB2RS/LSB4ES Cross-Check (SCON)
30
Propel Joystick
35
Propel Valve
40
Turntable Rotate Joystick
43
Footswitch Timeout
44
Jib Up/Down Joystick
48
PBMAS Safety Envelope (SCON)
49
Jib Up/Down Buttons
50
Jib Up/Down Flow Valve
52
Steer Joystick
53
Left Front Steer Sensor
54
Right Front Steer Sensor
55
Left Rear Steer Sensor
56
Right Rear Steer Sensor
59
Rocker Steer Joystick
61
PBMLS Safety Envelope (SCON)
63
Front Axle Sensor
64
Rear Axle Sensor
April 2018