ADJ 2.1 HCF Registration
Purpose
The purpose of this adjustment is to set HCF Side Edge Registration to within specification.
Check
1.
Load HCF with 8.5X11/A4 long edge feed paper.
2.
Make a 100% copy of Test Pattern 82P522 side A (USO) 82P521 side A (XL).
3.
Registration should be 5.0 +/-1.1mm
Reissue
DocuColor 12/DCCS50
(Figure
1).
Side Registration 5.0 +/-1.1mm
Figure 1 Checking the Registration
1/05
8a-29
High Capacity Feeder