Decurler Door Interlock Open Rap; Docking Interlock Open Rap - Xerox DocuColor 12/DCCS50 Service Manual

Table of Contents

Advertisement

11-302 Decurler Door Interlock Open RAP

Decurler Door Interlock Open Failure. This status code is declared when the Decurler Front
Cover is open.
Initial Actions
Refer to BSD12.1 for the following procedure.
Ensure that
P/J1033
on the Finisher PWB, and
Switch are connected before beginning this RAP.
Check the Front Cover for proper alignment.
Verify that the Front Cover closes properly.
Procedure
Enter dC330 012-302 Decurler Door Intlk Sw. The state of the Decurler Door Interlock
Switch is Low and switches to High when the Decurler Door is opened.
Y
N
With the Front Cover closed, there is +0 VDC between P/J1028-B6 on the Finisher
PWB and GND.
Y
N
Go to the
Flag 1
and
Flag 2
on BSD12.1. Check the wires for an open circuit. If the
wires are good, replace the Decurler Door Interlock Switch
continues, replace the Decurler PWB
the Finisher PWB
(PL
18.4).
Check the Decurler Door Interlock Switch for intermittent operation. Ensure that the
switch and the cover are properly aligned and adjusted. If the problem continues, replace
the Decurler PWB
(PL
18.6). If the problem continues, replace the Finisher PWB
18.4).
Check the Decurler Door Interlock Switch for intermittent operation. Ensure that the switch and
the cover are properly aligned and adjusted. If the problem continues, replace the Finisher
PWB
(PL
18.4).
Finisher/Sorter
11-302 Decurler Door Interlock Open RAP, 11-303
P/J1018
on the Decurler Door Interlock
(PL
18.11). If the problem
(PL
18.6). If the problem continues, replace
manuals4you.com
manuals4you.com

11-303 Docking Interlock Open RAP

Docking Interlock Open failure. This status code is declared when the Mailbox is not properly
docked.
Initial Actions
Refer to BSD12.1 for the following procedure.
Ensure that
P/J1028
on the Finisher PWB,
Switches,
P/J651
and
P/J652
RAP.
Check the Finisher/Mailbox for proper alignment.
Procedure
Enter dC330 012-303 Mailbox Docking INTLK Switches. The status of the Docking Inter-
lock Switches is High and changes to Low when the Mailbox is undocked.
Y
N
With the Finisher/Mailbox docked, there is +5 VDC between P/J1028-B7 on the Fin-
isher PWB and GND.
Y
N
Disconnect
P/J665
from the Docking Interlock Switch 2. With the Finisher/Mail-
box docked, there is +5 VDC between P/J1028-B7 on the Finisher PWB and
GND.
Y
N
Disconnect
P/J664
isher/Mailbox docked, there is +5 VDC between P/J1028-B7 on the Fin-
isher PWB and GND.
Y
N
(PL
Go to the
Flag
an short circuit to ground. If the wires are good, replace the Finisher PWB
(PL
18.4).
Replace the Docking Interlock Switch 1
Replace the Docking Interlock Switch 2
Check the Docking Interlock Switches for intermittent operation. Ensure that the switches
are properly aligned and adjusted. If the problem continues, replace the Finisher PWB
(PL
18.4).
Check the Mailbox Door Interlock Switch for intermittent operation. Ensure that the switch and
the cover are properly aligned and adjusted. Check that the Finisher/Mailbox is standing on an
even floor. Adjust Castors if necessary. If the problem continues, replace the Mailbox PWB
18.11).
1/05
8d-24
P/J664
and
P/J665
on the Docking Interlock
on the Decurler PWB are connected before beginning this
from the Mailbox Docking Interlock Switch 1. With the Fin-
10,
Flag 11
and
Flag 13
on BSD12.1. Check the wires for
(PL
18.6).
(PL
18.6).
DocuColor 12/DCCS50
(PL
Reissue

Advertisement

Table of Contents
loading

Table of Contents