5.5.3
Starting up mGuard pci² SD via BootP
In initial startup mode, the mGuard pci² additionally starts a BootP client on the internal net-
work interface (LAN 1). The BootP client is compatible with the "IPAssign" BootP servers
from Phoenix Contact as well as "DHCPD" under Linux.
This software can either be downloaded free of charge at
www.innominate.com
under "Downloads > Software".
IP address assignment using IPAssign is described in detail in "Assigning the IP address
using IPAssign.exe" on page 255.
If an non-configured mGuard pci² SD accesses a BootP server after booting, the BootP pro-
tocol assigns an IP address, a subnet mask, and optionally a default gateway of the internal
network interface to the mGuard pci² SD. These parameters are saved in the device which
can then be immediately accessed under these parameters.
Enter the address assigned via BootP in the browser: e.g., https://192.168.1.1/
Configure the mGuard as described in "Configuring the mGuard pci² SD" on page 97.