mGuard rs4000/rs2000 Switch
42
Innominate Security Technologies
2.4
Preparing the configuration
2.4.1
Connection requirements
–
The mGuard rs4000/rs2000 Switch must be connected to at least one active power
supply unit.
–
For local configuration: The computer that is to be used for configuration must be
connected to the LAN socket on the device.
–
For remote configuration: The device must be configured so that remote configura-
tion is permitted.
–
The device must be connected, i.e., the required connections must be working.
2.5
Configuration in Router mode
On initial startup, the mGuard can be accessed via the following address:
–
https://192.168.1.1
2.5.1
IP address 192.168.1.1
In Router mode, the mGuard can be accessed via the LAN interface via IP address
192.168.1.1 within network 192.168.1.0/24, if one of the following conditions applies.
–
The mGuard is in the delivery state.
–
The mGuard was reset to the default settings via the web interface and restarted.
–
The rescue procedure (flashing of the mGuard) or the recovery procedure has been
performed.
To access the configuration interface, it may be necessary to adapt the network configura-
tion of your computer.
Under Windows 7, proceed as follows:
•
In the Control Panel, open the "Network and Sharing Center".
•
Click on "LAN connection". (The "LAN connection" item is only displayed if a connection
exists from the LAN interface on the computer to a mGuard in operation or another part-
ner).
•
Click on "Properties".
•
Select the menu item "Internet protocol Version 4 (TCP/IPv4)".
•
Click on "Properties".
•
First select "Use the following IP address" under "Internet Protocol Version 4 Proper-
ties", then enter the following address, for example:
IP address:
Subnet mask:
Default gateway:
Depending on the configuration of the mGuard, it may then be necessary to adapt the net-
work interface of the locally connected computer or network accordingly.
–
192.168.1.2
255.255.255.0
192.168.1.1
I15007_en_02