5.5

Configuration in Stealth mode

The mGuard pci² SD can be started up in three different ways:
Start up the device in Stealth mode (standard)
Start up the device via temporary management IP address
Start up device via BootP
5.5.1
Start up the device in Stealth mode (standard)
Insert the mGuard pci² SD between an existing network connection.
To connect to the LAN and WAN interfaces, a suitable UTP cable (CAT5) is required. The
cables are not supplied as standard.
Connect the internal network interface (LAN 1) of the mGuard pci² SD to the corre-
sponding Ethernet network card of the configuration computer or a valid network con-
nection of the internal network.
Connect the external network interface (WAN 1) of the mGuard pci² SD to the external
network, e.g., Internet.
The STAT status LED lights up green when the supply voltage has been connected prop-
erly.
The mGuard boots the firmware. The STAT status LED flashes green during this time.
The mGuard is ready for operation as soon as the lower Ethernet socket LEDs light up. In
addition, the STAT status LED flashes green at heartbeat.
If the lower LEDs in the Ethernet sockets do not light up, this indicates a missing connec-
tion to the internal or external network. If no LED lights up, the supply voltage is missing.
The mGuard is configured via a web browser that is executed on the locally connected com-
puter.
NOTE: The web browser used must support SSL encryption (i.e., HTTPS).
The mGuard is preset and can be accessed via address https://1.1.1.1/